En esta página
15.133 14.5.24 Protocolo de referencia y revisión
15.133.1 Sistemas de referencia
- optical motion capture
- instrumented holds/force plates for boundary alignment
- IMU segment orientation
- manually reviewed multiview RGB-D
- surveyed wall/hold geometry
15.133.2 Metadatos mínimos
- subject code and anthropometrics
- route/scene revision
- camera and calibration IDs
- sampling rates/timestamps
- filter and derivative profiles
- phase/contact annotation revision
Revisión: A biomechanical/vision reviewer inspects derivative plots, edge masks, phase alignment and at least one 3D overlay before accepting a profile.
Acuerdo/anotación: For manually selected landmarks/events/targets, report agreement or adjudication process.